BOP Control Unit

  • Profile
  • Technical data
  • Media & Downloads

The KOLLER BOP Control Unit is a complete electrohydraulic system designed for the control and the operation of a BOP stack in the  hazard area.

One (1) Annular BOP 7 1/16 x 3,000 psi
One (1) Pipe Ram BOP 7 1/16 x 3,000 psi
One (1) Blind Ram BOP 7 1/16 x 3,000 psi

The design and calculation for:

Accumulator Volumetric Capacity
Pump Rating
Reservoir Volume

The BOP Control Unit is in accordance with API Specification 16D.

  • CE conform according machinery directive 2006/42/EG
  • one (1) 480 liter fluid reservoir
  • five (5) 50 liter hydropneumatic accumulators acc. PED
  • two (2) electric motor driven pumps with automatic pressure switch for start / stop
  • one (1) air operated double acting piston pump with automatic air pressure switch for start / stop

Specifications

Form factor 10 ft steel frame
ATEX identification EX II 2G II B T3
CE conform according machinery directive 2006/42/EG
Range of ambient temperature -20 / +40 °C

Hydraulic System

Maximum Working Pressure 207 bar / 3,000 psi
Pump flow rate 20 liter/min | 5.3 gallon/min
Close capacity for BOP‘s 38,8 liter/min | 10.25 gallon/min
Fluid reservoir 480 liter
Pressure Regulator One for Annular Pressure
One for BOP Manifold Pressure

Control Panels

Pressure Gauges 6 pieces with OD 100 mm
Signal / Control lamps 6 pieces for alarm / signal
Hand operated pneumatic valve for regulation of the annular working pressure
Remote control panel fully-electric operation of all three functions

Dimensions

Length 2,990 mm / 9.80 ft
Width 2,448 mm / 8.03 ft
Height 2,863 mm / 9.39 ft
Gross weight 4,000 kg / 8,818 lbs

Downloads

Go back